    当前位置:首页>横河模块

    ASI133-S00/SA3D0

    类别: 横河模块
    发布时间: 2021-03-13 10:28:16
    价格: ¥0
    发送联系信息 订购热线:13530116378
    详情
    横河模块ASI133-S00/SA3D0卡件ASI133-S00/SA3D0

    ASI133-S00/SA3S0      ASI533-S00/SS3S0             

    ASI133-H00/SA3S0      ASI533-H00/SS3S0            

    ASI133-S00/SA3D0      ASI533-S00/SS3D0            

    ASI133-H00/SA3D0     ASI533-H00/SS3D0            

    AST143-S00           ASR133-S00          ASD143-P00           ASD533-S00

    AST143-S00/ST4S0      ASR133-S00/SR3S0      ASD143-P00/SB4S0     ASD533-S00/SD3S0

    AST143-S00/ST4D0      ASR133-S00/SR3D0     ASD143-P00/SB4D0     ASD533-S00/SD3D0

    <Toc> <Ind> <D1.1 Regulatory Control Blocks> D1-9

    Input Signal Values (RV1, RV2, RV3)输入信号值

    The input signal values (RV1, RV2, RV3) are input data handled by the Signal selector blocks.输入信号值(RV1, RV2, RV3)是被信号选择器块用来处理的输入数据

    Use the Function Block Detail Builder to set the engineering unit and scale range of input signal values. The input signal values (RV1, RV2, RV3) are regarded as having the same engineering unit and scale range as those of the selected signal value (PV).通过功能块的Detail Builder设置输入信号值的工程单位和量程。这些输入信号值(RV1, RV2, RV3)被认作和PV值具有相同的工程单位和量程ASI133-S00/SA3D0

    Reset Limit Values (RLV1, RLV2)复位限制值

    The reset limit values (RLV1, RLV2) are input data that are handled by a controller block when the reset limit function is used.

    The reset limit values (RLV1, RLV2) are regarded as having the same engineering unit and scale range as those of the manipulated output value (MV). 当复位限制功能使用时,复位限制值(RLV1, RLV2)会作为一个控制块的输入数据被处理。这些复位限制值(RLV1, RLV2)被认作和MV具有相同的工程单位和量程ASI133-S00/SA3D0

    Input or Output Compensated Value (VN)输入或输出补偿值

    The engineering unit and scale range are not defined for input compensated values (VN) received from the BIN terminal, as the numeric data of input compensated values (VN) taken in from outside are used directly for input or output compensation computation.从补偿输入端BIN接收的输入补偿值(VN)没有指定工程单位和量程,因为从外部获得的输入补偿的数值是直接用于输入或输出补偿计算ASI133-S00/SA3D0

    Tracking Switch (TSW)跟踪开关

    The data handled by the tracking switch (TSW) for the TSI terminal must be an integer value of “0” or “1.” “1” and “0” indicate ON and OFF, respectively.

    跟踪开关输入端(TSI的被跟踪开关(TSW)处理的数据必须是0110分别指示ON OFF