    详情

    SM29氧化还原电极

    SM29-AU8氧化还原电极SM29-PT9厂价
    SM29 Redox Electrodes

    Redox measurements are a potentiometrical measurement of the oxidizing/reducing power of a liquid. To be able to measure this equilibrium of reversible redox reactions the electrodes used should be inert. Noble electrodes such as Platinum (Pt) and Gold (Au) are widely used for this purpose and seem to approximate the behaviour of an ideal inert electrode. Platinum is used most widely, has excellent chemical resistance but suffers slightly from chemosorption of Oxygen, which slows down its response.

    The potential of reference electrodes is depending on their

    composition. A table with the actual values for each system is given next. All values refer to 25°C. The reference system is also indicated on the textplate of the electrode.

     

     

     SM29-AU8氧化还原电极SM29-PT9厂价

    System

    Fill solution

    Value against Standard Hydrogen

    Electrode

    Ag/AgCl

    3.3 m. KCl

    203 mV

    Ag/AgCl

    sat. KCl

    196 mV

    Combined Redox Electrodes

    For redox measurement Yokogawa offers non-flow general purpose electrodes and a heavy duty flow electrode. All electrodes are equiped with a solid platinum pin to provide long

    lifetime, even in processes that harm the platinum electrodes such as hypochloride.

     

    METAL ELECTRODES

    l Polarisation free measurement by (patented) inert metal surface.

    l Dome shaped cup

    l Temperature range 0…130°C

    l Steam sterilisable.

    l Maximum process pressure: 1 MPa (10 bar)

    The Redox (ORP) electrode can be used in combination with all

    reference electrodes in the program of Yokogawa.

    The potential of reference electrodes is depending on their

    composition.

    A table with the actual values for each system is given next. All

    values refer to 25°C

     

    System

    Fitting

    Absolute value

    Value against SCE

    Ag/AgCl Ag/AgCl Calomel (SME)

    1 m KCl sat. KCl sat. KCl

    233 mV

    188 mV

    241 mV

    - 8 mV

    - 45 mV

    0 mV


    The reference system is also indicated on the textplate of the electrode

     

     SM29-AU8氧化还原电极SM29-PT9厂价

    TYPE

    TEMP. RANGE

    PROCESS PRESSURE

    METAL SURFACE

    SM29-AG8

    SM29-AU8

    SM29-PT9

    0…130°C

    0…130°C

    0…130°C

    maximum 1 MPa (10 bar)

    maximum 1 MPa (10 bar)

    maximum 1 MPa (10 bar)

    silver

    gold

    solid platinum